Features |
180 ~ 264 AC input range |
Protection: Short circuit / OLP / OVP |
|
Built in EMI filter & low ripple & noise |
|
Cooling by free air convection |
|
Small size, high power density |
|
Low cost, high reliability |
|
100% full load burn-in test |
|
1 year warranty |
Sr.no |
Parameters |
Specifications |
1) |
AC Input Voltage Range |
180 ~ 264 VAC |
2) |
Input frequency |
47 Hz to 450 Hz |
3) |
Leakage Current |
less than 1mA at 230VAC |
4) |
DC adjustment range |
-5% ~+10% |
5) |
Output Set Point Accuracy |
+/- 1.5% |
6) |
Over Load Protection |
110 to 150% of Rated Current for All O/P, Auto Recovery |
7) |
Short Circuit Protection |
Provided |
8) |
Over Voltage Protection |
>115% of Rated output Voltage using Transorb |
9) |
Temperature Coeffitient |
0.05%/deg.C |
10) |
Operating Temperature |
-10 TO +60 Deg.C |
11) |
Storage Temperature |
-20 TO +85 Deg.C |
12) |
Humidity |
95% RH at 40 Deg. C |
13) |
Fixed Converter Frequency |
>90KHZ |
14) |
Hold Up Time |
20 msec at 230 V AC and F.L.. |
15) |
Isolation |
a. Input to Output 3KV AC (1 min) |
b. Input to Chassis 1.5KV AC (1 min) |
||
c. Output to Chassis 500V DC (1 min) |
||
16) |
Connector |
Terminal block for input & output |
17) |
Dimensions |
Overall - 178 (L)x 107(W) x40 (H)mm |
UUEPL-250, 250W single output enclosed AC-DC power supply |
||||
P/NO. |
OUTPUT |
Tol. |
Ripple & Noise |
Efficiency |
UUEPL-250-5 |
+5V ,0~ 15A |
'+ 2% |
80mV |
77% |
UUEPL-250-12 |
+12V, 0~ 8.0A |
'+ 1% |
120mV |
81% |
UUEPL-250-15 |
+15V, 0~6.5A |
'+ 1% |
120mV |
82% |
UUEPL-250-24 |
+24V, 0-4.1A |
'+ 1% |
120mV |
83% |
UUEPL-250-48 |
+48V, 0~2.3A |
'+ 1% |
150mV |
85% |