Features

180 ~ 264 AC input range

Protection: Short circuit / OLP / OVP

Built in EMI filter & low ripple & noise

Cooling by free air convection

Small size, high power density

Low cost, high reliability

100% full load burn-in test

1 year warranty

SPECIFICATIONS OF 50W (UUEPL-50)

Sr.no

Parameters

Specifications

1)

AC Input Voltage Range

180 ~ 264 VAC

2)

Input frequency

47 Hz to 450 Hz

3)

Leakage Current

less than 1mA at 230VAC

4)

DC adjustment range

-5% ~+10%

5)

Output Set Point Accuracy

+/- 1.5%

6)

Over Load Protection

110 to 150% of Rated Current for All O/P, Auto Recovery

7)

Short Circuit Protection

Provided

8)

Over Voltage Protection

>115% of Rated output Voltage using Transorb

9)

Temperature Coeffitient

0.05%/deg.C

10)

Operating Temperature

-10 TO +60 Deg.C

11)

Storage Temperature

-20 TO +85 Deg.C

12)

Humidity

95% RH at 40 Deg. C

13)

Fixed Converter Frequency

>90KHZ

14)

Hold Up Time

20 msec at 230 V AC and F.L..

15)

Isolation

a. Input to Output 3KV AC (1 min)

b. Input to Chassis 1.5KV AC (1 min)

c. Output to Chassis 500V DC (1 min)

16)

Connector

Terminal block for input & output

17)

Dimensions

Overall - 106 (L)x 58.5(W) x40 (H)mm



UUEPL-50, 50W single output enclosed AC-DC power supply

P/NO.

OUTPUT

Tol.

Ripple & Noise

Efficiency

UUEPL-50-5

+5V ,0~ 8A

'+ 2%

75mV

73%

UUEPL-50-12

+12V, 0~ 3.5A

'+ 1%

100mV

78%

UUEPL-50-15

+15V, 0~2.8A

'+ 1%

100mV

80%

UUEPL-50-24

+24V, 0-2A

'+ 1%

100mV

82%