| PARAMETERS | CONDITIONS | ||
|---|---|---|---|
| INPUT | Voltage Range |
170V to 270VAC |
|
Phase |
Single Phase ( Line, Neutral and Earth ) |
||
Frequency |
47Hz to 53Hz |
||
Efficiency |
>80% @ 230VAC Input, Full load |
||
| RADIO OUTPUT | Voltage |
13.5V ± 0.2V, |
|
Current |
10A ( 135W max.) |
||
Line & Load Regulation |
<2% (without battery connected) |
||
Ripple ( 0 ~ 20MHz bandwidth) |
< 1% ( with 10uF & 0.1uF across the measuring point ) |
||
Noise ( 0 ~ 20MHz bandwidth ) |
< 2% ( with 10uF & 0.1uF across the measuring point ) |
||
Over Voltage Protection |
P.S.U. trips above 15V and resumes normal operation after input power recycling. |
||
Over Load / Short Circuit Protection |
Output folds back or goes in to 'Hickup' mode, if the current exceeds 110% of the rated current. |
||
| CHARGER OUTPUT | Voltage |
13.5V ± 0.2V ( will follow radio output setting, when battery is connected will follow battery voltage). |
|
Current |
6A ( Radio current <4.0A) |
||
Battery deep discharge cut-off |
Cut-off <10.8V, Reconnect >11.4 |
||
Battery reverse protection |
Battery is Cut-off from the output and a audiable alarm is activated |
||
| INDICATIONS | Output ON |
Indicates ‘ Output is Available' |
|
Battery ON |
Indicates ‘ Battery is supplying power to Radio'. |
||
Battery Low |
Indicates ‘ Battery is low and it is isolated from Radio'. |
||
Trickle Charge |
Indicates ‘ Battery is fully charged'. |
||
| ENVIRONMENT | Operating Temperature |
0º C to +50º C |
|
Storage Temperature |
0º C to +60º C |
||
Relative Humidity |
10% to 95% RH |
||
| GENERAL | Isolation Voltage |
1.5KV for 1minute with leakage current <5mA. a) Between Input and Output. b) Between Input and Chassis. |
|
Mechanical Dimensions |
Depth = 191mm, Width = 184mm, Height = 61mm. |
||
Weight |
2.2 Kgs. |
||