| Specifications | ||
|---|---|---|
PARAMETERS |
CONDITIONS |
|
INPUT |
Voltage Range |
170V to 270VAC |
Phase |
Single Phase ( Line, Neutral and Earth ) |
|
Frequency |
47Hz to 53Hz |
|
Efficiency |
>75% @ 230VAC Input, Full load |
|
RADIO OUTPUT |
Voltage |
13.5V ± 0.2V, |
Current |
15A ( 203W max.) |
|
Line & Load Regulation |
<2% (without battery connected) |
|
Ripple ( 0 ~ 20MHz bandwidth) |
< 1% ( with 10uF & 0.1uF across the measuring point ) |
|
Noise ( 0 ~ 20MHz bandwidth ) |
< 2% ( with 10uF & 0.1uF across the measuring point ) |
|
Over Voltage Protection |
P.S.U. trips above 15V and resumes normal operation after input power recycling. |
|
Over Load / Short Circuit Protection |
Output folds back or goes in to 'Hickup' mode, if the current exceeds 110% of the rated current. |
|
CHARGER OUTPUT |
Voltage |
13.5V ± 0.2V ( will follow radio output setting, when battery is connected will follow battery voltage). |
Current |
7A ( Radio current <8.0A) |
|
Battery deep discharge cut-off |
Cut-off <10.8V, Reconnect >11.4 |
|
Battery reverse protection |
Battery is Cut-off from the output and a audiable alarm is activated |
|
INDICATIONS |
Output ON |
Indicates ‘ Output is Available’ |
Battery ON |
Indicates ‘ Battery is supplying power to Radio’. |
|
Battery Low |
Indicates ‘ Battery is low and it is isolated from Radio’. |
|
Trickle Charge |
Indicates ‘ Battery is fully charged’. |
|
ENVIRONMENT |
Operating Temperature |
0º C to +50º C |
Storage Temperature |
0º C to +60º C |
|
Relative Humidity |
10% to 95% RH |
|
GENERAL |
Isolation Voltage |
1.5KV for 1minute with leakage current <5mA. a) Between Input and Output. b) Between Input and Chassis. |
Mechanical Dimensions |
Depth = 201mm, Width = 184mm, Height = 76mm. |
|
Weight |
2.5 Kgs. |
|