UU1315DM

PARAMETERS

CONDITIONS

INPUT

Voltage Range

170V to 270VAC

Phase

Single Phase ( Line, Neutral and Earth )

Frequency

47Hz to 53Hz

Efficiency

>80% @ 230VAC Input, Full load

RADIO OUTPUT

Voltage

13.5V ± 0.2V, Voltage Adjustable 12V to 14VDC

Current

15A ( 203W max.)

Line & Load Regulation

<2% (Without Battery Connection)

Ripple ( 0 ~ 20MHz)

< 1%

Noise ( 0 ~ 20MHz )

< 2%

Over Voltage Protection

P.S.U. trips above 15V and resumes normal operation after input power recycling.

Over Load / Short Circuit Protection

Output folds back or goes in to 'Hickup' mode, if the current exceeds 110% of the rated current.

CHARGER OUTPUT

Voltage

13.5V ± 0.2V ( will follow radio output setting, when battery is connected will follow battery voltage).

Current

7A ( Radio current <8.0A)

Battery deep discharge cut-off

Cut-off <10.8V, Reconnect >11.4

Battery reverse protection

Battery is Cut-off from the output and a audiable alarm is activated.

 

Metering

Analog meter (-)20 - 0 - 20(+) provided to read the voltage and current of Radio and Battery.

INDICATIONS

Output ON

Indicates ‘ Output is Available’

Battery ON

Indicates ‘ Battery is supplying power to Radio’.

Battery Low

Indicates ‘ Battery is low and it is isolated from Radio’.

Trickle Charge

Indicates ‘ Battery is fully charged’.

ENVIRONMENT

Operating Temperature

0º C to +50º C

Storage Temperature

0º C to +60º C

Relative Humidity

10% to 95% RH

GENERAL

Isolation Voltage

1.5KV for 1minute with leakage current <5mA. a) Between Input and Output. b) Between Input and Chassis.

Mechanical Dimensions

Length = 185mm, Width = 225mm, Height = 76mm.

Weight